HGL-63A~3150A电气性能参数与机械性能
额定发热电流Ith(A) |
63A |
100A |
160A |
|||||
额定电流lth(A) |
40 |
63 |
80 |
100 |
125 |
160 |
||
额定绝缘电压Ui(V) |
750 |
750 |
750 |
750 |
750 |
750 |
||
介质强度(V) |
5000 |
5000 |
5000 |
5000 |
5000 |
5000 |
||
额定冲击耐受电压UimpKV(安装类别IV) |
6 |
6 |
6 |
6 |
8 |
8 |
||
额定工作电流le(A) |
380V |
AC-21 |
40 |
63 |
80 |
100 |
125 |
160 |
AC-22 |
40 |
63 |
80 |
100 |
125 |
160 |
||
AC-23 |
40 |
63 |
80 |
100 |
125 |
160 |
||
660V |
AC-21 |
40 |
50 |
80 |
80 |
125 |
160 |
|
AC-22 |
32 |
32 |
50 |
50 |
125 |
160 |
||
AC-23 |
25 |
25 |
40 |
40 |
80 |
80 |
||
220V |
DC-21 |
40 |
63 |
80 |
100 |
125 |
160 |
|
DC-22 |
40 |
63 |
80 |
80 |
125 |
160 |
||
DC-23 |
40 |
63 |
63 |
63 |
125 |
125 |
||
440V |
DC-21 |
100 |
125 |
|||||
DC-22 |
100 |
125 |
||||||
DC-23 |
100 |
125 |
||||||
电动机功率P(KW) |
380V |
18.5 |
25 |
40 |
40 |
63 |
80 |
|
660V |
22 |
22 |
33 |
33 |
75 |
75 |
||
额定短时耐受电流Icw(KA Rms)0.1S/1S |
10/5 |
10/5 |
10/5 |
10/5 |
20/10 |
20/10 |
||
额定分断能力Icn(A Rms)AC23 380V |
320 |
504 |
640 |
800 |
1000 |
1000 |
||
额定接通能力lcm(A Rms)AC23 380V |
400 |
630 |
800 |
1000 |
1250 |
1250 |
||
额定短路接通能力Icm(KA峰值) |
7.5 |
7.5 |
10 |
10 |
12 |
12 |
||
机械寿命(循环操作次数) |
10000 |
10000 |
10000 |
10000 |
10000 |
10000 |
||
电气寿命(循环操作次数) 额定电压Ue=660V |
COSΦ=0.95 AC21 |
1700 |
1700 |
17000 |
1700 |
1500 |
1500 |
|
COSΦ=0.65 AC22 |
100 |
100 |
100 |
100 |
1000 |
1000 |
||
COSΦ=0.35 AC23 |
500 |
500 |
500 |
500 |
500 |
500 |
||
操作力距(Nm) |
1.2 |
1.2 |
1.2 |
1.2 |
6.5 |
6.5 |
额定发热电流Ith(A) |
250A |
630A |
1600 |
3150A |
||||||||||
额定电流lth(A) |
200 |
250 |
315 |
400 |
500 |
630 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
||
额定绝缘电压Ui(V) |
750 |
750 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
||
介质强度(V) |
5000 |
5000 |
8000 |
8000 |
8000 |
8000 |
10000 |
10000 |
10000 |
10000 |
10000 |
10000 |
||
额定冲击耐受电压UimpKV(安装类别IV) |
8 |
8 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
||
额定工作电流le(A) |
380V |
AC-21 |
200 |
250 |
315 |
400 |
500 |
630 |
1000 |
1250 |
1600 |
2000 |
2500 |
3150 |
AC-22 |
200 |
250 |
315 |
400 |
500 |
630 |
1000 |
1250 |
1600 |
2000 |
2000 |
3150 |
||
AC-23 |
200 |
250 |
315 |
340 |
425 |
536 |
|
|
|
|||||
660V |
AC-21 |
200 |
250 |
315 |
400 |
400 |
500 |
1000 |
1000 |
1600 |
2000 |
2500 |
2500 |
|
AC-22 |
160 |
160 |
315 |
315 |
315 |
315 |
800 |
800 |
800 |
1000 |
1000 |
1000 |
||
AC-23 |
100 |
125 |
125 |
125 |
125 |
125 |
|
|
|
|||||
220V |
DC-21 |
200 |
250 |
315 |
400 |
400 |
500 |
1000 |
1250 |
1600 |
2000 |
2500 |
12500 |
|
DC-22 |
200 |
250 |
315 |
400 |
400 |
500 |
1000 |
1250 |
1250 |
1600 |
1600 |
1600 |
||
DC-23 |
160 |
200 |
|
|
|
|
|
|
||||||
440V |
DC-21 |
160 |
200 |
315 |
400 |
400 |
500 |
1000 |
1250 |
1250 |
2000 |
2000 |
2000 |
|
DC-22 |
160 |
200 |
315 |
400 |
400 |
500 |
1000 |
1250 |
1250 |
1250 |
1250 |
1250 |
||
DC-23 |
160 |
200 |
315 |
400 |
400 |
500 |
1000 |
1000 |
1000 |
|
||||
电动机功率P(KW) |
380V |
100 |
132 |
160 |
220 |
280 |
315 |
560 |
560 |
560 |
710 |
710 |
710 |
|
660V |
90 |
110 |
185 |
185 |
185 |
185 |
475 |
475 |
475 |
750 |
750 |
750 |
||
额定短时耐受电流Icw(KA Rms)0.1S/1S |
30/12 |
30/12 |
45/20 |
45/20 |
50/25 |
50/25 |
90/50 |
90/50 |
90/50 |
90/50 |
90/50 |
90/50 |
||
额定分断能力Icn(A Rms)AC23 380V |
1600 |
1600 |
2500 |
3200 |
3200 |
3200 |
|
|
|
|||||
额定接通能力lcm(A Rms)AC23 380V |
2000 |
2000 |
3150 |
4000 |
4000 |
4000 |
|
|
|
|||||
额定短路接通能力Icm(KA峰值) |
17 |
17 |
30 |
30 |
40 |
40 |
|
|
|
|||||
机械寿命(循环操作次数) |
10000 |
10000 |
5500 |
5500 |
5500 |
5500 |
4000 |
4000 |
3000 |
|
||||
电气寿命(循环操作次数) 额定电压Ue=660V |
COSΦ=0.95 AC21 |
1500 |
1500 |
750 |
750 |
750 |
750 |
600 |
600 |
450 |
2500 |
2500 |
2500 |
|
COSΦ=0.65 AC22 |
1000 |
1000 |
500 |
500 |
500 |
500 |
400 |
400 |
300 |
|
|
|
||
COSΦ=0.35 AC23 |
500 |
500 |
250 |
250 |
250 |
250 |
200 |
200 |
150 |
|
|
|
||
操作力距(Nm) |
10 |
10 |
14.5 |
14.5 |
14.5 |
14.5 |
37 |
37 |
60 |
60 |
60 |
60 |